Graco Pro Xp 60 WB Instructions Manual page 10

Hide thumbs Also See for Pro Xp 60 WB:
Table of Contents

Advertisement

Gun Overview
Error
Error Display
Error
Display
Display
If the Smart module loses communication with the
power supply, the Error display appears, the Hz
indicator turns red, and the Smart module is disabled.
See the following figure and
This can occur in Operating Mode or Diagnostic
Mode. See
Electrical Troubleshooting, page
Communication must be restored to make the Smart
module functional.
Note
It takes 8 seconds for the Error display to
appear. If the gun has been disassembled,
wait 8 seconds before spraying to ensure
that an Error condition has not occurred.
Note
If there is no power to the gun, the Error
display will not appear.
Figure 3 Error Display
Adjusting the
the Low
Low Voltage
Voltage Setting
Adjusting
Adjusting
the
Low
Voltage
The low voltage setting is user adjustable. To
access the low voltage setting screen when in
Operating Mode, press the LO SET button (LS)
momentarily. The screen will display the current
low voltage setting. See the following figure and
Smart Gun Key, page
11. The range is 30–60 kV.
Set the Voltage Adjustment switch (VA) to LO. Press
the LO SET button repeatedly to increase the setting
in increments of 5. When the display reaches the
maximum setting (60 kV) it will return to the minimum
setting (30 kV). Continue pressing the button until
you reach the desired setting.
10
Smart Gun Key, page
11.
46.
Setting
Setting
Note
After 2 seconds of inactivity the display will
return to the Operating Screen.
Note
The low voltage setting may be locked. See
Lock Symbol, page
Figure 4 Low Voltage Setting Screen (Unlocked)
Lock
Lock Symbol
Lock
Symbol
Symbol
The low voltage setting may be locked. When locked,
an image (LK) appears on the screen. See the
following figure and
Smart Gun Key, page
• When in HI mode, the low voltage setting is always
locked. The lock symbol will appear when the LO
SET button is pressed.
• When in LO mode, the lock symbol will
only appear if the lock is enabled. See
only
only
Low Voltage Lock Screen, page
unlock the low voltage setting.
Figure 5 Low Voltage Setting Screen (Locked)
10.
11.
always
always
13, to lock or
3A7504A