17.3 Parameter selection (ParameterCall) submenu
The submenu is visible only if the ParameterView parameter is active
(ParameterView) ( p. 83). The settings for a parameter can be changed
directly here.
To change the parameters:
1. Select the menu Service > ParameterCall (Service > Parameter
2. Press the OK button to confirm the selection.
A window appears where the parameter can be selected:
Fig. 56: ParameterCall (Parameter selection) submenu
3. Select the level of the desired parameter with the
4. Use the
5. Use the
6. Use the
7. Enter the parameter value and confirm by pressing OK.
66
selection).
ParameterCall
Lvl
Cat Par Mode
T
01 00
Abbreviation
button to move to the Cat category and select the desired
►
value with the
▲/▼
buttons or the number keys. The categories are
explained in the Parameter list 878-M PREMIUM.
button to move to the Par parameter and select the desired-
►
▲/▼
value with the
buttons or the number keys. The parameters are
explained in the Parameter list 878-M PREMIUM.
button to move to the fourth value on the far right. This value
►
may vary, depending on the parameter. It may be a mode or a window
with an action selection.
6
Meaning
O
Operator
T
Technician
Service Instructions 878-M PREMIUM - 03.0 - 10/2019
Programming
+
▲/▼
buttons.