Setting The Output Configuration (Outputconfig) Parameter - DURKOPP ADLER 878-M PREMIUM Service Instructions Manual

Hide thumbs Also See for 878-M PREMIUM:
Table of Contents

Advertisement

Programming
A mode can be allocated for every input (parameter T 53 00).
The following table lists the modes:
Menu item
Mode
Stored

17.6.4 Setting the Output configuration (OutputConfig) parameter

Configure and allocate the outputs here. The table shows the outputs and
their allocation. The pins on the circuit board are labeled and must be allo-
cated according to the table, depending on what was connected to the pin.
Machine output signal
ML (X22)
NK (X22)
RA (X16)
Service Instructions 878-M PREMIUM - 03.0 - 10/2019
Setting options
0
No function
1
Threading position
2
Bartack active/inactive.
3
Manual bartack
4
Half stitch
5
Full stitch
6
Point position
8
Needle height
11
2. Needle thread tension
12
Change of stitch length
15
Seam center guide/feed dog
18
Light barrier
20
Operation lock when contact is opened normally (NO)
21
Quick stroke height adjustment
23
Change to next seam section
25
2nd position of edge guide
26
Sewing foot lightening
27
2nd fullness degree value
29
Puller
31
Motor blockage inverse
32
Motor blockage in seam
44
Short stitch length
On – stored
OffOff – not stored
Output
X120B.9
X120B.10
X120B.12
85