Software Settings; Parameter Settings For Classes 867 And 867-M - DURKOPP ADLER 867 Additional Instructions

Remaining thread monitor
Hide thumbs Also See for 867:
Table of Contents

Advertisement

2.4 Software settings

2.4.1 Parameter settings for classes 867 and 867-M

DAC classic control
Parameter
Operator level
o 06 00
o 06 05
o 06 06
o 06 07
Technician level
t 06 00
t 06 01
t 06 02
t 06 03
t 06 04
t 06 06
t 06 06
14
Assembling the remaining thread monitor
Value
Function
4
Remaining thread monitor
0 - 9999
Number of stitches for the remaining thread
monitor
0 - 1
Stop sewing motor when the counter
reaches 0
0 = No
1 = Yes
0 - 1
Sewing foot stays down after thread cutting
0 = No
1 = Yes
0 - 2
Activation of the remaining thread monitor
0 = Off
1 = Right
2 = Left & right
0 - 1
Remaining thread monitor mode
0 = Dynamic
1 = Static
0.0 - 3.300 V
Threshold right
0.0 - 3.300 V
Intensity right
0.0 - 3.300 V
Threshold left
0.0 - 3.300 V
Intensity left
0 - 1
Confirmation required after warnings
0 = No
1 = Yes
Additional Instructions 867/867-M PREMIUM - 00.0 - 07/2018