17.5.14 Setting the Material thickness detection (FabricThickness)
Various settings can be made for material thickness detection.
The options are explained in more detail in the table.
Menu item
On/Off
Hysterese
PressureComp
17.5.15 Setting the Correction of the effects of high speeds
Various settings can be made for correcting the effects of high speeds.
The options are explained in more detail in the table.
Menu item
Hysterese
80
parameter
Setting options
Material thickness detection active/inactive.
Tolerance at which the material thickness detection based on
whether
the second stitch length, the second needle thread tension and/or
the second sewing foot stroke switches back. This tolerance is
designed to ensure that there is no constant alternating between
activation and deactivation in the boundary range.
(Value range 0.0 – 2.0 [mm])
With extremely thick material, the foot pressure increases above the
standard set value due to the thickness of the material. To a certain
extent, the machine can compensate itself for the influence of thick
material.
(Value range On/Off)
(SpeedCorr) parameter
Setting options
Tolerance at which the correction of the effects of high speeds based
on whether the second stitch length, the second needle thread tension
and/or the second sewing foot stroke switches back. This tolerance is
designed to ensure that there is no constant alternating between
activation and deactivation in the boundary range.
(Value range 0 – 2000 [rpm])