Hardware Description
Item
AC input voltage
MTBF
MTTR
Availability
Slot quantity
Redundant MPUs
Redundant Switch fabrics
Redundant fans
Redundant power supply
Forwarding performance
Switching capacity
Operating temperature
Storage temperature
Relative operating humidity
Relative storage humidity
Long-term operating altitude
Storage altitude
Issue 01 (2018-05-03)
Specification
input voltage range: 180 V to 264 V
input rated voltage: 200 V to 240 V
21.91 years
0.5 hours
0.999997395
11
1:1
2+1
2 assemblies
Support for proper fan operation in case of a single
fan failure for a short period at 40° C (104° F)
2+2
2880 Mpps (LPUF-240)
7.08 Tbps (LPUF-240/LPUI-240)
Long-term: 0° C to 45° C (32° F to 113° F)
Short-term: –5° C to +55° C (23° F to131° F)
Remark: Restriction on the temperature variation
rate: 30° C/hour (86° F/h)
–40° C to +70° C (–40° F to +158° F)
Long term: 5% to 85% RH, non-condensing
Short term: 5% to 95% RH, non-condensing
5% to 95% RH, non-condensing
<= 4000 m (13123.2 ft.) (For the altitude in the range
of 1800 m to 4000 m [5905.44 ft. to 13123.2 ft.], the
operating temperature of the NEU100 must decrease
by 1° C [33.8° F] for every 220 m [721.78 ft.].)
Less than 5000 m (16404 ft.)