NE40E
Hardware Description
Item
Redundant MPUs
Redundant Switch fabrics
Redundant fans
Redundant power supply
Forwarding performance
Switching capacity
Operating temperature
Storage temperature
Relative operating humidity
Relative storage humidity
Long-term operating altitude
Storage altitude
1.7.6 NE40E-X16A
Overview
Table 1-12 Device attributes
Product Type
NE40E-X16A
DC
Issue 01 (2018-05-03)
Specification
1:1
3+1
2 partitions
2 assemblies/partition, each partition in support for
proper fan operation in case of a single fan failure
for a short period at 40° C (104° F)
4+4
5760 Mpps (LPUF-240)
12.58 Tbps (LPUF-240/LPUI-240)
Long-term: 0° C to 45° C (32° F to 113° F)
Short-term: –5° C to +55° C (23° F to131° F)
Remark: Restriction on the temperature variation
rate: 30° C/hour (86° F/h)
–40° C to +70° C (–40° F to +158° F)
Long term: 5% to 85% RH, non-condensing
Short term: 5% to 95% RH, non-condensing
5% to 95% RH, non-condensing
<= 4000 m (13123.2 ft.) (For the altitude in the range
of 1800 m to 4000 m [5905.44 ft. to 13123.2 ft.], the
operating temperature of the NEU100 must decrease
by 1° C [33.8° F] for every 220 m [721.78 ft.].)
Less than 5000 m (16404 ft.)
Description
BOM
NE40E-X16A
02359914
Integrated DC
Chassis
Components(In
1 Hardware Description
Model
Earliest
Software
Version
CR5B0BKP167
V800R006C20
3
97