Huawei NE40E Hardware Description page 261

Hide thumbs Also See for NE40E:
Table of Contents

Advertisement

NE40E
Hardware Description
Name
RUN (green)
ALM (red)
ACT (green)
Optical interface
L/A
MGMT-ETH
LINK (green)
MGMT-ETH ACT
(yellow)
Table 1-192 Management interfaces
Interface
Name
FSP0,
FSP1
GE/10GE
MGMT-E
TH
Console
Issue 01 (2018-05-03)
Description
Before the board is powered on and registers, this indicator status
changes in the following sequence: off > blinks quickly > steady
on > blinks quickly > steady on > blinks slowly (0.5 Hz).
After the board is powered on and registers, if this indicator blinks at
0.5 Hz, the system is working properly.
If this indicator is steady on, an alarm is generated.
If this indicator is off, no alarm is generated.
If this indicator is steady on, the board functions as the master one.
If this indicator is off, the board functions as the slave one.
Reserved.
If this indicator is steady on, the link is Up.
If this indicator is off, the link is Down.
If this indicator is blinking, data is being transmitted and received.
If this indicator is off, no data is being transmitted or received.
Interfac
Connec
e Type
tor
Type
Serial
RJ45
interface
SFP+/S
GE/10GE
FP
Ethernet
RJ45
interface
(10M/100
M/1000
M
Base-TX
autonegot
iation)
RS-232
RJ45
serial
interface
Description
Cable
Reserved. It
-
functions as an
interface for
fast chassis
switchovers.
Reserved
-
cascading
interface.
It connects to
Super category 5 shielded twisted
an NMS and
pair
can work in
half-duplex or
full-duplex
mode.
It connects to
8-core shielded cable
the console for
on-site system
configuration.
Baud rate: 9600
1 Hardware Description
247

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents