System Power Supply Architecture - Huawei NE40E Hardware Description

Hide thumbs Also See for NE40E:
Table of Contents

Advertisement

NE40E
Hardware Description
Table 1-42 Power supply examples
Overall Power
Consumption
P<3000W
3000W≤P<6000W
6000W≤P<9000W
9000W≤P<12000W
Table 1-43 describes recommended power supply configurations. You can choose the PM
configuration based on the actual platform.
Table 1-43 Recommended configurations
Power Supply Scenario
-48 V DC power supply
AC power supply
240 V HVDC power supply
380 V HVDC power supply

1.8.4.2 System Power Supply Architecture

NE40E-X8A uses the non-partitioned power supply architecture. NE40E-X8A backplane has
one area, which houses two power inputs converged on backplane.
-48 V DC Power Supply
As shown in Figure 1-41, the NE40E-X8A has two PEMs. Each PEM has eight inputs. There
are altogether 16 inputs (8 inputs on each of area A and area B). Each PM has two inputs. The
two inputs are from power supply areas A and B, respectively. The PM converts the power
and outputs the power to the power supply backplane. In this manner, power supply areas A
and B back up each other A maximum of 8 PMs can be configured based on the N+1 backup
mechanism.
Issue 01 (2018-05-03)
If PMs are not fully configured, power cables are routed only for the PEM interfaces whose
corresponding PMs are installed. To facilitate the deployment of new power cables during capacity
expansion of PMs, you are advised to configure the PMs from the top down and leave a filler panel in
the position where no PM is not installed.
PM Configuration
A1,B1
A1,B1,A2,B2
A1,B1,A2,B2,A3,B3 A1,B1,A2,B2,A3,B3 3+3
A1,B1,A2,B2,A3,B3
,A4,B4
PEM Cabling
A1,B1
A1,B1,A2,B2
A1,B1,A2,B2,A3,B3
,A4,B4
400G
3+1
3+3
3+3
3+3
1 Hardware Description
N+N Backup
1+1
2+2
4+4
1T Bundle
5+1
4+4
4+4
4+4