Hide thumbs Also See for NE40E:
Table of Contents

Advertisement

NE40E
Hardware Description
Indicator
Technical Specifications
Item
Dimensions (H x W x D)
Weight
Rated input voltage
Input voltage range
Maximum input current
Maximum output power
Typical power consumption
Typical heat dissipation

1.8.6.7 AC PEM

The AC PEM is used to connect the AC power supply. Each PEM provides four power inputs.
The two terminals on the right side are connected to the power supply plane on the client side,
Issue 01 (2018-05-03)
Color
The AC power system supports 200-240 V AC power. It supports 110 V dual-live-wire inputs but not
110 V AC single-phase inputs. If 110 V dual-live-wire inputs are used, the voltage must range from 180
V to 264 V.
240V HVDC power system, the input voltage range from 192 V to 288 V DC. 380V HVDC power
system, the input voltage range from 260 V to 400 V.
Normal
Abnormal
Status
Status
Specification
41.5 mm x 107 mm x 437 mm(1.63 in x 4.21 in x 17.2
in)
2.0 kg(4.41 lb)
200 V AC to 240 V AC (220V)
240V DC/380V DC
180 V AC to 264 V AC
192V DC to 400V DC
16 A
3000 W
182 W
590.5 BTU/hour
1 Hardware Description
Abnormal
Reason
voltage.
The device
is powered
off due to
overcurrent
or short
circuit.
The current
of modules
is seriously
imbalanced.
166