NE40E
Hardware Description
Item
Slot quantity
Redundant MPUs
Redundant Switch fabrics
Redundant fans
Redundant power supply
Forwarding performance
Switching capacity
Operating temperature
Storage temperature
Relative operating humidity
Relative storage humidity
Long-term operating altitude
Storage altitude
Issue 01 (2018-05-03)
Specification
22
1:1
3+1
[400G bundle] 2 partitions; 2 assemblies/partition;
each partition in support for proper fan operation in
case of a single fan failure for a short period at
40° C (104° F)
[1T bundle] 2 partitions; 3 assemblies/partition;
each partition in support for proper fan operation in
case of a single fan failure for a short period at
40° C (104° F)
[400G bundle] DC: 6+1
[400G bundle] HVDC&AC: 5+5
[1T bundle] DC: 9+1
[1T bundle] HVDC&AC: 7+7
5760 Mpps (LPUF-240)
50.32 Tbps (LPUI-1T)
Long-term: 0° C to 45° C (32° F to 113° F)
Short-term: –5° C to +50° C (23° F to 122° F)
Remark: Restriction on the temperature variation
rate: 30° C/hour (86° F/h)
–40° C to +70° C (–40° F to +158° F)
Long term: 5% to 85% RH, non-condensing
Short term: 5% to 95% RH, non-condensing
5% to 95% RH, non-condensing
<= 4000 m (13123.2 ft.) (For the altitude in the range
of 1800 m to 4000 m [5905.44 ft. to 13123.2 ft.], the
operating temperature of the NEU100 must decrease
by 1° C [33.8° F] for every 220 m [721.78 ft.].)
Less than 5000 m (16404 ft.)
1 Hardware Description
103