Warmline - Siemens HiPath 1100 Series Programming Manual

Table of Contents

Advertisement

Programming an Extension
Step by Step
62
Deactivating the Hotline Mode
Required: Programming Mode must be active (*95
31994).
Enter the code for programming.
4 5
Enter the extension number (e.g., 12/102) for which you
want to remove a Hotline assignment.
*
The Hotline Mode is deactivated.
Enter the next extension number
or
Press this key.
#
Initial state for Programming Mode.

Warmline

Specify the length of time the extension should wait to
call the first number configured as a Hotline. Assuming
the timeout is 9 seconds, the call will be made 9
seconds after the handset is lifted. However, if during
the 9 second time interval a key is pressed on the
phone keypad, the call to the Hotline will be canceled.
Each extension can have a different timeout for activat-
ing a Hotline. This timeout may vary from 0 to 9
seconds.
By default, the Hotline activation timeout is "0 seconds".
Required: Programming Mode must be active (*95
31994).
Enter the code for programming.
6 2
Enter the extension number (except 11/101, for
example, 12/102) for which you want to change the
timeout.
...
Enter the length of time (0 to 9 seconds) for the Hotline
0
9
timeout.
Enter the next extension number
or
Press this key.
#
Initial state for Programming Mode.