Programming an External Line
Step by Step
Wait 5 seconds
*
*
40
Wait for a confirmation tone.
Initial state for Programming Mode.
Auto-Seizure Mode for an External
Line
This allows dialing an external call when the handset is
lifted, without using an access code (e.g., 0). When this
setting is selected, you must enter a code to dial inter-
nal calls or activate the Extension key.
Required: Programming Mode must be active (*95
31994).
Enter the code for programming.
0 3 6
or
Activate/Deactivate auto-seizure:
#
*
= To activate
= To deactivate (default)
#
Initial state for Programming Mode.

False Tone

This send an external line dial tone even when there is
no external line available.
Required: Programming Mode must be active (*95
31994).
Enter the code for programming.
0 6 3
or
Activate/Deactivate a false tone:
#
= Deactivated for Argentina and India
#
*
= Activated for all other countries (default)
Initial state for Programming Mode.
If no value is entered, Dial Tone Detection will
not be activated.
When option 0 (Automatic ID) is selected, the
activation of this feature may impact the
programming of the Dialing Mode. It is recom-
mended that you reconfigure the Dialing Mode
(Pulse or Tone) for the extensions.