Sensor Activation Logic; Time Between Attempts For Activating The Sensor - Siemens HiPath 1100 Series Programming Manual

Table of Contents

Advertisement

Relay and Sensor on the HiPath 1120
Step by Step
0
128
= Deactivate the sensor's function (default)
0
= Dial the number specified in "Number Dialed by
1
Sensor Activation" (Code 052).
= Activate the relay through the sensor
2
= Detect DTMF code. When this setting is selected,
3
the number that was called must acknowledge or
ignore an alarm call by sending an acknowledge-
ment code ("#" DTMF signal )
Press this key.
#
Initial state for Programming Mode.

Sensor Activation Logic

The sensor's main position can be set as follows:
Contacts are closed. The sensor is activated when
contacts are open.
Contacts are open. The sensor is activated when
contacts are closed.
Required: Programming Mode must be active (*95
31994).
Enter the code for programming.
7 4
or
Select the main position for the sensor:
1
= Contacts closed (default)
0
= Contacts open
1
Press this key.
#
Initial state for Programming Mode.
Time between Attempts for Activating the
Sensor
This setting specifies a timeout after which a new
attempt is made to call an internal or external number,
assuming that the line was busy on the previous
attempt.
The default setting is 3 minutes.
Required: Programming Mode must be active (*95
31994).