Programming
Timing Chart
Example 2: Read Set for Normal Memory Allocations
Description and Conditions
Downloaded from
Elcodis.com
electronic components distributor
1 cycle
A20011
(1 cycle ON)
23201
23202
23203
23204
23205
23206
23207
200200
(Write request)
200608
(Write complete)
In addition to the above, CIO 23201 will turn ON for one cycle on the rising edge
of SW2-2 (CIO 200701). One cycle after CIO 23208 turns ON, CIO 200200
(write request) will turn ON.
Example: The following data is read from the indicated addresses:
Loop 1 PV: D0000
Loop 1 control output variable: D0001
Loop 2 heater current: D0002
This read program is to be executed after writing the data with program
example 1.
Conditions: C200H-TC001 (thermocouple)
SW202 set to 2 (K).
Unit number set to 0 (allocated memory: CIO 2000 to CIO 2009.
SW2-1 set ON (Normal) and SW2-2 set ON (CPU Unit).
: Point of Write command execution
Section 4-3
55