Memory Allocation - Omron SYSMAC C200H-TC Operation Manual

Table of Contents

Advertisement

Memory Allocation

4-1
Memory Allocation
Memory Allocation
CS1
CIO area
Unit#0 CIO 2000 to CIO 2009
Unit#1 CIO 2010 to CIO 2019
Unit#2 CIO 2020 to CIO 2029
Unit#3 CIO 2030 to CIO 2039
Unit#4 CIO 2040 to CIO 2049
Unit#5 CIO 2050 to CIO 2059
Unit#6 CIO 2060 to CIO 2069
Unit#7 CIO 2070 to CIO 2079
Unit#8 CIO 2080 to CIO 2089
Unit#9 CIO 2090 to CIO 2099
C200HX/HG/HE, C200HS, or C200H
IR area
Unit#0 IR 100 to IR 109
Unit#1 IR 110 to IR 119
Unit#2 IR 120 to IR 129
Unit#3 IR 130 to IR 139
Unit#4 IR 140 to IR 149
Unit#5 IR 150 to IR 159
Unit#6 IR 160 to IR 169
Unit#7 IR 170 to IR 179
Unit#8 IR 180 to IR 189
Unit#9 IR 190 to IR 199
Selecting Allocated Data
36
Downloaded from
Elcodis.com
electronic components distributor
The Temperature Control Unit is allocated 10 words in the IR or CIO Area ac-
cording to the unit number switch setting on the front of the Unit. These words
are used as an I/O refresh data area. The IR or CIO Area words used by the Tem-
perature Control Unit are refreshed each I/O refresh scan of the CPU Unit.
During PC I/O refresh,
each scan is executed for
the outputs (PC to Temper-
ature Control Unit) followed
by the inputs (Temperature
Control Unit to PC).
During PC I/O refresh, each
scan is executed for the outputs
(PC to Temperature Control Unit)
followed by the inputs (Tempera-
ture Control Unit to PC).
Note A Duplicate I/O Unit error occurs if the set Unit number corresponds to the num-
ber of an existing Special I/O Unit.
The data allocated to each IR word due to the Unit number setting is determined
by the setting of SW2-1 on the front of the Unit.
ON
Normal
OFF
Fixed
This setting becomes valid immediately after the switch is set.
Temperature Control Unit
I/O refresh data area
Wd (n)
to
Output refresh
Wd (n+2)
Wd (n+3)
to
Input refresh
Wd (n+9)
(n=2000 + 10 x Unit number)
The terms "output" and "input" are defined
from the CPU Unit.
Temperature Control Unit
I/O refresh data area
Wd (n)
to
Output refresh
Wd (n+2)
Wd (n+3)
to
Input refresh
Wd (n+9)
(n=100 + 10 x Unit number)
The terms "output" and "input" are defined
from the CPU Unit.
All data can be set using commands.
Fixed data is allocated to memory. Direct reading and writing
of data is possible.
Section 4-1