Emc & Earthing Requirements; Additional Earthing - Avaya INDeX 30 Installation & Maintenance

Table of Contents

Advertisement

Preparing for Installation
EMC & Earthing Requirements

Additional Earthing

Installation & Maintenance
INDeX 30
The INDeX 30 system is EMC approved and carries CE mark approval. For an
installation to be EMC compliant, it must meet the following requirements at all
times:
– Only EMC approved INDeX equipment must be used.
– You must install a cabinet with it's front cover in place.
– You must only use EMC cables (i.e. cables in which the sheath includes a braid
and foil barrier).
– The mains supply must provide an earth connection.
If correctly installed, the INDeX 30 is earthed via its power supply connections.
However, in some locations local regulations may require connection of an additional
safety earth.
When the optional Battery Kit is installed, an addition safety earth must be fitted
(see page 12).
Connection of an additional safety earth can be done as detailed below. Note that
Avaya do not supply any parts for this connection.
– Connecting an Additional Safety Earth
Prepare a suitable earth lead with termination for an M6 bolt or screw, maximum
length 12mm. Using the bolt or screw, attach the cable to the threaded insert
provided adjacent to the INDeX 30 cabinets mains input socket.