The system collects details of equipment faults during normal operation. It can
output these faults either later as a fault report or when they occur as a real-time
fault log.
The system loses all fault details following a system reset. Some false faults are
generated during a normal power-up. It is sensible to clear these using the Clear
faults command after starting the system.
To print a fault report :
1. From the Administration menu, select Reports and then Fault Report.
2. Use the up and down cursor keys to select the port on which to output the
report.
3. Select Print faults and enter either a device directory number or * for all device
faults.
To clear all stored faults :
1. From the Administration menu, select Reports and then Fault Report.
2. Select Clear faults and enter either the directory number of the device or * for
all device faults.
Each line on the fault report or log has the following parts:
– Site Code : The sites network node number.
– Prefix : Fixed as "ALM"
– Fault Priority : 1 = Major alarm, 2 = minor alarm, 3 = warning, 4 = information
(e.g. alarm cleared).
– Fault Code:
Code
Description
14
ISDN frame synchronisation lost.
20
Extension disconnected/failed.