5.4.1

Automatic Restart with dynamic input testing

+24V
Fuse
5A F
A1
Power
supply
circuit
A2
0V
5.4.2

Automatic Restart without dynamic input testing

+24V
Fuse
5A F
A1
Power
supply
circuit
A2
0V
Page 18 of 79
T11
T12
T21
T22
T31
Safety
Safety
Restart
Input 1
Input 2
Safety Output
Auxiliary Output
Control
14
24
T11
T12
T21
T22
T31
Safety
Safety
Restart
Input 1
Input 2
Safety Output
Auxiliary Output
Control
14
24
T32
Function setting:
DIP Switch 1 ON = Automatic Restart
DIP Switch 2 ON = Dynamic input testing Enabled
Description:
EDM
E-Stop pushbutton connected to T12 and T22
Remarks:
Control
Wiring is using the dynamic test pulses.
Applicable up to Ple acc. EN ISO 13849-1
Output connections and EDM not shown in this schematic
44
T32
Function setting:
DIP Switch 1 ON = Automatic Restart
DIP Switch 2 OFF = Dynamic input testing Disabled
Description:
EDM
E-Stop pushbutton connected to T12 and T22
Remarks:
Control
Applicable up to Pld acc. EN ISO 13849-1
Output connections and EDM not shown in this schematic