Product family – General information
1.1

Intended use

The G9SR units are intended for the functions listed in the table below:
E-Stop function
Door monitoring (safety limit switches)
Door monitoring (key operated switches)
Door monitoring (non-contact switches)
ESPE monitoring
Additional safety outputs
Note on the G9SR-EX unit:
The extra outputs realised with the G9SR-EX units have an ON-delay timer and an OFF-
delay timer for additional control of your outputs.
1.2

Family Overview

The product family G9SR consists of a G9SR-BC□-□ (BC = Basic), a G9SR-AD□-□
(AD = Advanced) and a G9SR-EX□-T90-□ unit (EX = Extension) to give you flexibility
when configuring your specific system.
1.2.1

G9SR-BC

The G9SR-BC has a double channel safety input that can be used
in E-Stop, door monitoring applications or applications with
opto-electronic safety sensors.
The G9SR-BC has solid state safety outputs for DC loads of up
to 2A and with a peak current up to 5A.
The G9SR-BC can operate standalone or as an additional input
with a G9SR-AD.
See also:
Chapter 6 G9SR unit: G9SR-BC□-□ on page 19.
G9SR-BC
G9SR-AD
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
No
G9SR
G9SR-EX
No
No
No
No
No
Yes