Automatic Restart; Wiring Examples Automatic Restart - Omron G9SR Series Operation Manual

Safety relays
Hide thumbs Also See for G9SR Series:
Table of Contents

Advertisement

Operation manual
5.3

Automatic Restart

If automatic restart is selected, the safety outputs will be activated as soon as the safety
inputs are active and the ON-delay has expired.
Automatic Restart Diagram
ON
T12
OFF
T22
Restart
Not used
Output
G9SR-BC/AD
Output
G9SR-EX
WARNING!
5.4

Wiring examples Automatic Restart

Wiring of the Restart function is similar for the G9SR-BC and the G9SR-AD units.
Two wiring examples for Automatic Restart:
tOn
tOn: ON-delay time set on the G9SR-EX
tOff: OFF-delay time set on the G9SR-EX
The Automatic Restart option shall only be used when it is
guaranteed that activation of the OSSDs cannot create a
dangerous situation. Do not use this option in any other case.
tOff
G9SR
t
Page 17 of 79