Interlogix FlexZone Series Product Manual page 81

Table of Contents

Advertisement

Local control mode
In local control mode, the two Aux inputs are used to activate electronic self-tests
(AUX1 = A-side, AUX2 = B-side). To activate the self-test function, close a
momentary switch across the input. You must close the momentary switch for the
time specified in the Filter Window. Leave the AUX inputs open if you do not
want to use the self-test function.
Remote control mode
In Remote control mode, the two Aux inputs serve as auxiliary device inputs to
the host Security Management System (SMS). The inputs are available for
reporting the status of other security devices. The processor reports any change
of an input's state to the SMS via the Silver Network Manager. Table 2 below
includes the selectable Remote Control input wiring configurations, and Table 3
on page 75 includes the selectable supervision resistor values.
Table 2: Selectable input configurations
Input option
UCM selection
Unsupervised
Single resistor
supervision
Dual resistor
supervision
Unsupervised
Single resistor
supervision
Dual resistor
supervision
Table 3: Selectable resistor values
R1 values (single resistor
supervision)
820
1 k
1.1 k
FlexZone™ Product Guide
Alarm relay Supervision
NO
A
NO
1
A
S
NO
1
2
A
S
NC
A
NC
1
S
A
NC
1
2
A
S
R1 values (double resistor
supervision)
1.1 k
2.2 k
4.3 k
Chapter 3: Calibration and setup
R1
relay
---
---
NC
5.1 k
NO/NC
4.3 k
---
---
NO
5.1 k
NO/NC
5.1 k
R2 values (double resistor
supervision)
820
1.1 k
2.2 k
R2
---
---
820
---
---
820
75