Figure 54: FlexZone processor wiring diagram
T4
power
self-test/auxiliary
input
AUX 1
POWER
-
+
-
T4 power output for
T7
T4
processors receiving
power over sensor
cables
- DC GND
+ 12 to 48 VDC
auxiliary/self-test inputs
-
AUX input 1
+
-
AUX input 2
+
relay 1 NC
relay 1 COM
relay 1 NO
relay 2 NC
relay 2 COM
relay 2 NO

Silver Network wiring connections

Note:
A network interface card is required to enable Silver Network
communications between a FlexZone processor and the Silver Network
manager.
Note:
For groups of FlexZone processors that communicate over the sensor
cables, only the processor that is connected directly to the Silver Network
requires an NIC.
Silver Network specifications
Data rate - fixed 57.6 k bps
Maximum 60 devices spread over up to 4 independent network loops
Two communication Channels (Side A, Side B)
Response time - 1 second, or less from alarm source to Network Manager
(per loop)
Network termination - not required
Transmission media/maximum separation distances between processors:
EIA-422 copper wire - 1.2 km (0.75 mi.) - 2 pairs per Channel
Multi-mode fiber optic cable (820 nm) - 2.2 km (1.4 mi.) - 2 fibers per
Channel - optical power budget 8 dB
FlexZone™ Product Guide
T7
relay outputs
inputs
AUX 2
RELAY 1
RELAY 2
NC COM NO
NC COM NO
+
-
+
T8
T8
A-Side
sensor cable
RELAY 3
RELAY 4
A-SIDE
NC COM NO
NC COM NO
-
-
+
T9
Chapter 2: Installation
T9
B-Side
B-SIDE
-
-
+
B SIDE sensor cable
- shield
+ center conductor
- shield
A SIDE sensor cable
- shield
+ center conductor
- shield
relay 4 NO
relay 4 COM
relay 4 NC
relay 3 NO
relay 3 COM
relay 3 NC
47