Chapter 2: Installation
Installing cable on chain-link
Figure 27: Installation procedure diagram
start point post
spacing
20-30 cm
a
g
e
f
1. Dispense the sensor cable alongside the installation location on the secure
side of the fence. Do not allow the sensor cable to fall off the spool, as it may
twist and kink. (The FlexZone cable should have been deployed at the
installation location for the conditioning procedure.)
2. Beginning at the start point of the zone, attach the sensor cable to the fence
fabric (point a). Leave enough extra sensor cable at this point to install a
splice kit, or form a service loop and connect the sensor cable to the
processor (app. 1 m).
3. Hold the sensor cable straight and level along the fence while you attach the
cable to the fence fabric beside the second post at point b. Ensure that there
is no slack in the sensor cable.
4. Attach the cable to the fence at point c.
5. Attach the cable to the fence beside the second post at point d.
6. Return to the start point and install cable ties every 25 to 30 cm along the first
fence panel at points e to j.
7. Hold the sensor cable straight and level along the fence while you attach the
cable to the fence fabric beside the third post at point k.
8. Attach the cable to the fence at point l.
9. Attach the cable to the fence beside the third post at point m.
10. Return to the first post and install cable ties every 25 to 30 cm along the
second fence panel at points n to r.
11. Repeat this procedure, one fence panel at a time, until the cable is fully
installed.
12. Verify that there are no slack or loose sections of cable, and that the cable
ties are properly tightened. Trim and properly discard the ends of the cable
ties.