Sensor Cable Supervision - Interlogix FlexZone Series Product Manual

Table of Contents

Advertisement

Figure 65: FlexZone network connections
422/FO(A)<>Coax(B)
422/FO
Coax
synchronization signal (out A in B)

Sensor cable supervision

You must specify the sensor cable supervision method for each connected
FlexZone sensor cable. Several other functions depend on this setting
including power and data distribution over the sensor cables as well as
auxiliary power output.
1. Select the Side A Cfig tab.
2. In the Cable Side Configuration field, select the Cable Supervision Mode for
the Side A cable:
Figure 66: FlexZone sensor cable supervision
EOL resistor supervision
3. Repeat for the Side B cable.
4. Save and download the configuration changes to the processor.
Adjacent Processor (m) setting
If the selected cable side is connected to another processor via the sensor
cables, you must specify the total length of sensor cable between the 2
processors:
1. Select the Side A Cfig tab.
2. Select the total length of the 2 connected sensor cables from the Adjacent
Processor (m) drop down menu:
Figure 67: FlexZone sensor cable supervision
3. Repeat for the Side B cable (if necessary).
4. Save and download the configuration changes to the processor.
FlexZone™ Product Guide
Coax(A)<>422/FO(B)
Coax + 422/FO
network communication data flow
Cable pair/loop supervision
(enables power over sensor cables function)
specify the length of cable between the 2 processors
Chapter 3: Calibration and setup
Coax(A)<>Ethernet Ethernet<>Coax(B)
63

Advertisement

Table of Contents
loading

This manual is also suitable for:

Flexzone-4Flexzone-60

Table of Contents