Figure 43: Sensor cable terminations steps 11 & 12
dual cable guide bars
center the terminator CCA between the dual cable guide bars
13. Attach the enclosure to the fence. Form a 20 cm drip loop and install the
enclosure horizontally to protect the cable entry points from rain and run off.
Figure 44: Mounting the termination enclosure

Installing sensor cable on gates

This section provides details about protecting swinging gates with FlexZone
sensor cable.
Gates usually require the same level of protection as the fence.
Install the sensor cable on the side of the fence into which the gate panel
opens.
If the gate panel opens in the opposite direction, or both directions, leave
enough slack in the sensor cable so that the gate can be fully opened in
either direction.
Make sure that there is no loose sensor cable when the gate is closed.
Run the cable from the fence to the gate at the hinged side of the gate, and
then back to the fence on the same side.
Ensure that the cable cannot be caught and pinched when the gate opens
and closes.
Run the cable once completely around the gate in a diamond pattern, app. 30
cm from the edge (respect the minimum bend radius - no sharp corners).
FlexZone™ Product Guide