Installing Cable On Rigid Fences; Sensor Cable Connections - Interlogix FlexZone Series Product Manual

Table of Contents

Advertisement

Chapter 2: Installation
Figure 29: Double pass cable installation
B side cable
matching
start points
e.g., 2 m
A side cable

Installing cable on rigid fences

The technique used to install sensor cable on rigid fences depends on the type,
and brand, of fence. In some instances, cable ties are used to attach the sensor
cable. Some manufacturers offer cable clamps that are specific to their fence
type (see Figure 30 below). Service loops, sensitivity loops and zone
demarcation loops are not recommended on rigid fence types. Contact our
Customer Service for applications advice if you are considering installing the
FlexZone sensor on a rigid fence type.
Figure 30: Palisade fence with FlexZone sensor cable on top rail
FlexZone sensor cable
custom cable
clamps

Sensor cable connections

There are three FlexZone sensor cable connections: processor connections,
splices and terminations. The sensor cable to processor connections are made
30
max. 300 m
service loop
cable tie spacing
identical
consistent for
features
both passes
zone demarcation loop
matching
end points at
terminators
e.g., 275 m
Impasse® II high-security
palisade fence
FlexZone™ Product Guide

Advertisement

Table of Contents
loading

This manual is also suitable for:

Flexzone-4Flexzone-60

Table of Contents