Figure 71: Defining cable segments
The assigned Zone label is centered at the top
No Zone label for segments assigned to Zone 0
Use the Delete button to merge the selected
segment with the preceding segment
1. Below the Segment Setting window, select the Split button. The selected
cable segment is divided into 2 sections, the white section is the currently
selected Segment.
2. Use the Range (m) spin control to enter the meter at which this cable
segment begins.
Note:
You can also drag the zone boundary to the appropriate point in the
profile window.
3. Use the Zone: spin control to assign the segment to an alarm Zone (label the
zone according to the site plan; more than one cable segment can be
assigned to an alarm zone).
Note:
Any sections of detecting cable that should NOT report alarms must be
assigned to Zone 0 (e.g., cable bypasses across gates).
4. Repeat this procedure to define each cable segment and zone, as specified in
the site plan.
5. Save the UCM file and download the configuration data to the processor.
6. Repeat this procedure for the B Side sensor cable.
Setting the endpoint of detecting cable
Use the results of the location tap testing to specify the end point of the detecting
cable.
1. Select the last defined cable segment (the segment that includes the meter at
which detection ends).
2. Select the Split button.
3. Use the Range (m) spin control to enter the meter at which detection ends.
4. Use the spin controls to assign the last Segment to Zone 0.
FlexZone™ Product Guide
of the segment
Magnification buttons
Chapter 3: Calibration and setup
2
3
1