Fax Service Setting - Ricoh SP 330DN Service Manual

Hide thumbs Also See for SP 330DN:
Table of Contents

Advertisement

Maintenance Mode (for Touch Panel Models)

Fax Service Setting

Menu
Modem
RX Level
Settings
TX Level
Cable Equalizer
Protocol
Training Retries
Definition
Encoding
Protocol
T0 Timer
Definition
Timer
T1 Timer
T4 Timer
RX Settings
CNG Tone
Detection
CNG Cycles
Tone Sound
Monitoring
M0C3/M0C4/M0C5/M0C6/M0C7
Sets the reception level.
[-43 dBm (Default)/ -33 dBm/ -26 dBm/ -16 dBm]
Sets the transmission level.
[-15 to -1 / -9(Default)/ 1dBm/ step]
These selectors are used to improve the pass-band
characteristics of analogue signals on the telephone line.
[0Km (Default)/ 1.8Km/ 3.6Km/ 7.2Km]
This sets the number of training retries to be repeated before
automatic fallback.
[1 Time/ 2 Times (Default)/ 3 Times/ 4 Times]
Sets the compression method for Tx/Rx.
[MMR+MR+MH (Default)/ MR+MH/ MH]
Timeout for response from the called station in automatic
sending mode
[35 Sec/ 45 Sec/ 55 Sec (Default)/ 60 Sec/ 90 Sec/ 140 Sec]
Set the time length for the T1 timer.
[40 Sec (Default)/ 50 Sec]
Set the time length for the T4 timer.
[3 Sec (Default/ 4.5 Sec]
CNG tone detection time (RX mode : FAX / TEL, FAX / TAD
Only)
After the line is connected via the external telephone, the
machine can detect a CNG signal for the time length specified
by this setting.
[5 Sec (Default)/ 10 Sec]
Number of CNG cycles to be detected
This setting is only effective for FAX/TAD mode.
[1.5 Cycle (Default)/ 2.0 Cycle]
Determines the period when tones from the line are
monitored.
5-22