Service Program Mode
"SYSTEMver x.xx/ 1. Service" shows on the display.
NOTE:If you switch the machine off, any jobs stored on the hard disk using the sample print
and protected print features will be deleted.
Check first with the user tools to see if there are any jobs stored with these features (Menu
key - Sample Print, or Protected Print).
Method 2: Press the "Up/Down arrow" keys together for about 5 seconds, and then press
the "OK" key.
"SYSTEMver x.xx/ 1. Service" appears on the display.
The machine automatically goes off line when you enter the service mode.
Accessing the Required Program
Use the "Up/Down arrow" keys to scroll through the menu listing.
1.
Service: Controller service modes
2.
Engine: Engine service modes
3.
End: Exit service mode
To select an item, press the "OK" key. Then the sub-menu shows.
Scroll through the sub menu items using the "
To go back to a higher level, press the "Escape" key.
Inputting a Value or Setting for a Service Program
Enter the required program mode as explained above. The setting appearing on the display
is the current setting.
Select the required setting using the "
value remains if the "OK" key is not pressed.
Exiting Service Mode
Select "End" from the service mode main menu, then press the "OK" key.
To make the settings effective, turn the main switch off and on after exiting service
mode.
G190
" keys.
" keys, then press the "OK" key. The previous
5-2
SM