Status Instructions; Reader_Status - Siemens SIMATIC Ident Function Manual

Hide thumbs Also See for SIMATIC Ident:
Table of Contents

Advertisement

Configuring the instructions
4.5 Programming instructions
4.5.4

Status instructions

4.5.4.1

Reader_Status

The "Reader_Status" instruction reads status information from the reader or
communication module (RF18xC/RF18xCI with the "CM configuration_1" module). For
the various reader families, there are different status modes that you can select using
the "ATTRIBUTE" parameter.
Figure 4-20 Instruction "Reader_Status"
Table 4- 33 Explanation for the instruction "Reader_status"
Parameter
ATTRIBUTE
IDENT_DATA
54
Data type
Default values
SINT
0x81
SINT[10]
0
Description
Identifier of the status modes / pos-
sible entries:
RF200: 0x81
RF300: 0x81, 0x86
RF300 (Gen2): 0xEF
RF61xR, RF68xR: 0x89
RF18xC, RF18xCI: 0xA2
Result values depending on
ATTRIBUTES
Note:
When necessary, an array of any size
can be transferred to this parameter.
Note that the array must be ≥ 10
bytes long (e.g. "SINT[12400]").
Ident profile, Add-on instruction for Rockwell systems
Function Manual, 07/2020, C79000-G8976-C410-04

Advertisement

Table of Contents
loading

Table of Contents