198
Installing the Avaya™ S8700 Media Server with Avaya™ MCC1 or SCC1 Media Gateway
Installing and Wiring Telephones
Connections for Telephone Used for Emergency Transfer and as Normal Extension
Figure notes
1
2
3
Install Telephones Used Only for Emergency
Transfer (Trunk/Auxiliary Field)
Connect a pair of wires between the -48V and GRD terminals on the yellow emergency
1
transfer row/connecting block and the EM TRANS RELAY PWR terminal. See
''Connections for Telephone Used for Emergency Transfer'' on page
2
Connect Central Office (CO) trunk leads from the purple field to TC terminals on the
yellow emergency transfer row/connecting block for each trunk.
Connect CO trunk leads from the green field to TK terminals on the yellow emergency
3
transfer row/connecting block for each trunk.
10
35
2820
3
4
5
TC
TK
LC
ST
TC
TK
LC
ST
TC
1M
1m
2M
2m
3M
3m
3w
ALARM MONITORS
To Network Interface Facility
To Blue or White Station Distribution
Field
To TN2183 or Equivalent Analog Line
Circuit Pack
ST
ST
EMXR
7
6
7
8
TK
LC
ST
TC
TK
LC
ST
TC
TK
LC
EM TRANS RELAY PWR
4
To TN747B (or Equivalent) Central
Office Trunk Circuit Pack
To Power Transfer Unit
5
6
To Control Carrier Auxiliary
Connector
May 2003
C
C
C
N
N
N
N
N
G
O
O
O
ST
-48
O
C
C
O
C
R
M
M
M
1
2
1
2
3
D
V
1
2
3
ACC PWR
r758582b MMR 042996
197.