4-Pair Station Circuits; 3-Pair To 4-Pair Station Circuit Distribution - Avaya S8700 Installing Manual

Media gateway
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Installing the Avaya™ S8700 Media Server with Avaya™ MCC1 or SCC1 Media Gateway
127
Connect the MDF to Stations and PSTN
Lists of terminals that can be connected to the S8700 Multi-Connect configuration are provided
in
''Connectable Telephone and Consoles'' on page
163.

4-Pair Station Circuits

Four-pair circuits, via station cables, can be run directly from an equipment room MDF to a
258A or BR2580A adapter as shown in
''4-Pair Circuit Distribution and Connectivity'' on page
128. The 4-pair station cables connect the adapter to the information outlets.
The 4-pair station cables can be run directly from the equipment room to the information outlets
if 4-pair terminal blocks are used in the distribution field. See
''4-Pair Run to Equipment Room
or Satellite Location'' on page
129. The station cables must be field-terminated on the 110-type
terminal blocks.
If 110-type terminal blocks are used with a modular plug-ended station cable, an adapter can be
connected directly to the 110-type terminal block connectors. See
''4-Pair Run to Equipment
Room or Satellite Location'' on page
129.

3-Pair to 4-Pair Station Circuit Distribution

''3-Pair to 4-Pair Satellite Location Connectivity'' on page 130
shows the 3-pair circuit
distribution from an equipment room MDF to a satellite location using 110-type hardware.
Four-pair circuits are distributed from the satellite location to the information outlets.
May 2003

Advertisement

Table of Contents
loading

This manual is also suitable for:

G600

Table of Contents