2.5

Communication

The 3WL10 air circuit breaker can be integrated into an industrial communication network via
communication modules for remote monitoring and remote operation of a circuit breaker.
The communication modules are used with the electronic releases of ETUs of the 6-series.
Depending on the communication modules used, the following protocols are available:
● Modbus RTU via RS485 (COM042)
● Modbus TCP via Ethernet and other IP communication (COM043)
● PROFIBUS DP (COM040)
● PROFINET IO (COM041)
● IEC 61850 (COM044)
Up to two different communication modules can be installed at the same time so that
connection to the communication systems is possible with different protocols.
More information
You will find detailed information on communication interfaces of circuit breakers in the
3WL10 communication manual (see Chapter Product-specific information (Page 7)).