Fan Motor Error - Xerox Phaser 6128MFP Service Manual

Hide thumbs Also See for Phaser 6128MFP:
Table of Contents

Advertisement

Fan Motor Error

Phaser 6128MFP Service Manual
Troubleshooting Procedure Table (continued)
Step
Actions and Questions
7
Check for +24 V at J22 on the MCU
Board.
Is +24 V available at J22-2 and J22-
4 when the Interlock Switch is
closed?
The Fan has failed. The following troubleshooting procedure applies to this error.
Applicable Error
042-358: Fan Motor Error
Initial Actions
Cycle printer power.
If the problem persists, follow the procedure below.
Troubleshooting Reference Table
Applicable Parts
Fan, PL10.6.7
LVPS, PL106.16
MCU Board, PL10.7.7
LVPS Harness, PL10.8.3
Troubleshooting Procedure Table
Step
Actions and Questions
1
Run the Fan test (DO-1e or DO-1f)
(page 4-46):
Does the Fan rotate?
2
Check P/J503 on the LVPS.
Is the connection secure?
3
Check the Main LVPS harness
continuity. Disconnect P/J501from
the LVPS and P/J14 from the MCU
Board.
Is the harness damaged?
Error Messages and Codes
Yes
Replace the
Sub Drive
Assembly
(page 8-60).
Wiring and Plug/Jack Map References
"Map 1 - MCU Board" on page 10-6
"Map 3 - Electrical and Drive" on page 10-8
"LVPS" on page 10-14
Yes
Replace the
MCU Board
(page 8-57).
Go to step 3.
Repair or
replace the
LVPS Harness
(PL10.8.14).
No
Replace the
MCU Board
(page 8-57).
No
Go to Step 2.
Connect the
Fan.
Go to step 4.
3-103

Advertisement

Table of Contents
loading

Table of Contents