Kubota GL6000A-AU-B Workshop Manual page 91

Diesel generator
Table of Contents

Advertisement

GL6000A-AU-B, GL6000D-AU-B,GL9000A-AU-B, GL9000D-AU-B, WSM
Nozzle Holder Assembly and Glow Plug
1. Remove the overflow pipe (1).
2. Remove the nozzle holder assemblies (2).
3. Remove the copper gasket (5) and heat seal (6).
4. Remove the lead (3) from the glow plugs (4).
5. Remove the glow plugs (4).
(When reassembling)
• Replace the copper gasket and heat seal with new one.
Overflow pipe retaining nut
Tightening torque
Nozzle holder assembly
Glow plug
(1) Overflow Pipe
(2) Nozzle Holder Assembly
(3) Lead
Nozzle Heat Seal Removal Procedure
IMPORTANT
• Use a plus (phillips head) screw driver (1) that has a
diameter which is bigger than the heat seal hole (Approx.
6 mm (0.2 in.)).
1. Drive screw driver (1) lightly into the heat seal hole.
2. Turn screw driver three or four times each way.
3. While turning the screw driver, slowly pull the heat seal (4) out
together with the injection nozzle gasket (3).
4. If the heat seal drops, repeat the above procedure.
(When reassembling)
• Heat seal (4) and injection nozzle gasket (3) must be changed
when the injection nozzle is removed for cleaning or for service.
(1) Plus Screw Driver
(2) Injection Nozzle
1-S29
ENGINE
20 to 24 N·m
2.0 to 2.5 kgf·m
15 to 18 lbf·ft
49 to 68 N·m
5.0 to 7.0 kgf·m
37 to 50 lbf·ft
7.9 to 14 N·m
0.80 to 1.5 kgf·m
5.8 to 10 lbf·ft
(4) Glow Plug
(5) Copper Gasket
(6) Heat Seal
9Y1211607ENS0040US0
(3) Injection Nozzle Gasket
(4) Heat Seal
9Y1211607ENS0041US0
KiSC issued 06, 2016 A