Diesel generator
Table of Contents

Advertisement

GL6000A-AU-B, GL6000D-AU-B,GL9000A-AU-B, GL9000D-AU-B, WSM
CAUTION
• When removing the radiator cap, wait at least 10 minutes after the engine has stopped and cooled down.
Otherwise, hot water may gush out, scalding nearby people.
Radiator Cap Air Leakage
1. Set a radiator tester and adaptor (BANZAI Code No.: RCT-2A-
30S) on the radiator cap.
2. Apply the specified pressure 90 kPa (0.9 kgf/cm
measure the time for the pressure to fall to 60 kPa (0.6 kgf/cm
9 psi).
3. If the measurement is less than the factory specification,
replace the radiator cap.
Pressure falling time
Factory specification
Radiator Water Leakage
1. Pour a specified amount of water into the radiator.
2. Set a radiator tester and an adaptor (BANZAI Code No.:
RCT-2A-30S) and raise the water pressure to the specified
pressure.
3. Check the radiator for water leaks.
4. For water leak from the pinhole, repair with the radiator cement.
When water leak is excessive, replace the radiator.
Radiator water leakage
Factory specification
test pressure
1-S17
ENGINE
9Y1211607ENS0015US0
2
, 10 psi), and
2
,
More than 10 seconds for
pressure fall from
90 → 60 kPa
2
0.9 → 0.6 kgf/cm
,
10 → 9 psi
9Y1211607ENS0016US0
160 kPa
2
1.6 kgf/cm
23 psi
9Y1211607ENS0017US0
KiSC issued 06, 2016 A