Kubota GL6000A-AU-B Workshop Manual page 159

Diesel generator
Table of Contents

Advertisement

GL6000A-AU-B, GL6000D-AU-B,GL9000A-AU-B, GL9000D-AU-B, WSM
Safety Switch Continuity
1. Open the engine room door (1).
2. When the safety switch (2) is turned ON and OFF, measure the
resistance between the terminals of it each time.
3. (a) when the measurement are the above table value.
The safety switch (2) is normal.
(b) when the measurement are out of the above table value.
The safety switch (2) is failure, then please exchange it.
ON
Resistance
OFF
(1) Engine Room Door
Lamp Timer (for Glow Plug)
1. Remove the lamp timer from inside of the panel.
2. Connect the battery (4), lamp timer (1) and bulb (2) as shown in
the figure.
3. The bulb (2) light up when contacting the lead wire 1 (3) with
positive terminal of the battery (4) and goes off approximately
6 seconds late, the lamp relay is proper.
(1) Lamp Timer for Glow Plug
(2) Bulb
2-S14
GENERATOR
Infinity
0 Ω
(2) Safety Switch
9Y1211607GRS0016US0
(3) Lead Wire 1
(4) Battery (12 V)
9Y1211607GRS0017US0
KiSC issued 06, 2016 A

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gl9000a-au-bGl9000d-au-bGl6000d-au-b

Table of Contents