Pilot Box
1. Continuity should exist between the terminals for each lamp.
2. If there is no continuity, change the lamp.
Charge
3 terminal – 4 terminal
Water temperature
2 terminal – 8 terminal
Oil pressure
7 terminal – 8 terminal
Glow
1 terminal – 5 terminal
(1) Pilot Box
(2) Charge
(3) Water Temperature
2-S17
GENERATOR
Approx. 10 Ω
(4) Oil Pressure
(5) Glow