Regulator
1. Start the engine.
2. Measure the output voltage of the regulator with a circuit tester.
Output Voltage
Terminal 6 – Terminal 2
3. When the measurement is not the above table value, measure
the input voltage of the regulator with a circuit tester.
Input Voltage
Terminal 1 – Terminal 3
4. When the measurement is the above table value, the regulator
is failure. Replace it.
NOTE
• When the input voltage of the regulator is out of
specification, check a dynamo.
(1) Terminal 1
(2) Terminal 2
(3) Terminal 3
2-S15
GENERATOR
14 V to 15 V
Approx. 14 V
(4) Terminal 4
(5) Terminal 5
(6) Terminal 6