Electrical System - Kubota GL6000A-AU-B Workshop Manual

Diesel generator
Table of Contents

Advertisement

GL6000A-AU-B, GL6000D-AU-B,GL9000A-AU-B, GL9000D-AU-B, WSM

(5) Electrical System

CAUTION
• To avoid accidental short circuit, be sure to attach the positive cable to the positive terminal before the
negative cable is attached to the negative terminal.
• Never remove the battery cap while the engine is running.
• Keep electrolyte away from eyes, hands and clothes. If you are spattered with it, wash it away completely
with water immediately.
• Keep open sparks and flames away from the battery at all times. Hydrogen gas mixed with oxygen
becomes very explosive.
Battery Voltage
1. Stop the engine.
2. Measure the voltage with a circuit tester between the battery
terminals.
3. If the battery voltage is less than the factory specification, check
the battery specific gravity and recharge the battery.
Battery voltage
Factory specification
(1) Positive Terminal
1-S21
ENGINE
9Y1211607ENS0025US0
More than 12 V
(2) Negative Terminal
9Y1211607ENS0026US0
KiSC issued 06, 2016 A