Kubota GL6000A-AU-B Workshop Manual page 167

Diesel generator
Table of Contents

Advertisement

GL6000A-AU-B, GL6000D-AU-B,GL9000A-AU-B, GL9000D-AU-B, WSM
Rotor Assembly
1. Remove the cooling fan (2).
2. To avoid damage to the rotor assembly (1), suspend the rotor
assembly (1) with a sling belt enough to keep it from lifting, and
leave it suspended.
3. Remove the rotor assembly mounting screws.
4. Remove the rotor assembly (1), take care not to damage the
winding.
(When reassembling)
• Clean any oil and dirt from the mounting surfaces of the rotor
and flywheel. If this is not done correctly, it will result in damage
of rotor and stator caused by loose fittings.
• Handle carefully to avoid damaging the winding.
Cooling fan mounting
screw
Tightening torque
Rotor
assembly
mounting
screw
(1) Rotor Assembly
Replacing Ball Bearing
1. Hook the puller until it clicks onto the outer bearing ring and then
pull off the bearing.
(When reassembling)
• Keep new bearing sealed until use.
• Clean dirt from the bearing housing.
• When tapping in the bearing, press it by tapping on the inner
race gently with special tool.
(1) Ball Bearing
2-S22
GENERATOR
20 to 27 N·m
2.0 to 2.8 kgf·m
15 to 20 lbf·ft
GL6000A-AU-
35 to 44 N·m
B,
3.5 to 4.5 kgf·m
GL6000D-AU-
26 to 32 lbf·ft
B
GL9000A-AU-
20 to 27 N·m
B,
2.0 to 2.8 kgf·m
GL9000D-AU-
15 to 20 lbf·ft
B
(2) Cooling Fan
9Y1211607GRS0028US0
9Y1211607GRS0029US0
KiSC issued 06, 2016 A