List of Self Tests

Installation and Verification Manual
The Self Test comprises of several tests. Each test consists of a
number of sub tests. A brief description of each test is given
below.
The Self Test can be run in one of two modes Run > All Tests or
Run > Selected Test.
The Run All Tests mode runs all the tests from the following
list.
The Run Selected Test allows an individual test to be selected
from the following list.
Test Title
1
Platform Test
2
Confidence Test
3
Optical Power Test
4
DCC Add/Drop Test
5
6
7
Frequency Test
8
9
Long Gating Test
Self Test Overview
Description
This is for factory use only. It performs basic
test of the CPU memory and IDE interface.
This test checks all the optical and the
electrical paths for SONET/SDH, PDH/DSn,
but not for Ethernet. A basic signal continuity
check is performed. This involves verifying
the signal configuration by
injecting/detecting a single error.
This test checks both the data paths and the
optical power measurement circuitry.
The test checks the data paths associated
with the DCC add/drop hardware. The DCC
loopback should be fitted for this test.
Not currently applicable.
Not currently applicable.
This test checks the data path through the
clock offset and frequency measurement
hardware. The test checks the absolute clock
offset frequency result.
Not currently applicable.
This test is for factory use only.