Test Description
111
step 8
111
step 9
112
step 10
112
step 10
112
step 11
112
step 12
113
step 14
Option 121
111
step 4
111
step 5
111
step 8
111
step 9
112
step 10
112
step 10
112
step 11
112
step 12
113
step 14
All options
113
Check Receiver Sensitivity margin v.s.
Transmitter Extinction Ratio
Electrical Pulse Mask and Output Characteristics
DS1 Output Mask Tests
117
step 4
118
step 5
Installation and Verification Manual
'No Trouble' Min Sens
Additional Attenuation
–20dBm PWR meas
OC-192/STM-64
Frequency
–9 dBm PWR meas
'No Trouble' Max Sens
Power Meter check
Laser LED ON
Note Attenuator Setting
'No Trouble' Min Sens
Additional Attenuation
–20dBm PWR meas
OC-192/STM-64
Frequency
–9 dBm PWR meas
'No Trouble' Max Sens
Power Meter check
DS1 ANSI Mask
DSX-1 Pulse Amplitudes
Result
Min
Actual
Pass/Fail
Typ > 1 dB
–12.5 dBm
9953.2799 MHz
+0 dBm
Pass/Fail
step 11,+2 dB
Pass/Fail
N/A
Pass/Fail
Typ > 1 dB
–15.5 dBm
9953.2799 MHz
+0 dBm
Pass/Fail
step 11,+2 dB
Pass/Fail
Pass/Fail
Pass/Fail
Performance Tests
Max
N/A
–9.5 dBm
9953.2801 MHz
–7.5 dBm
step 11,–2 dB
N/A
N/A
–11.5 dBm
9953.2801 MHz
–6.5 dBm
step 11,–2 dB