Genie GS-2669 Service And Repair Manual page 73

Hide thumbs Also See for GS-2669:
Table of Contents

Advertisement

Service and Repair Manual
Ground Controls
5
Install the new level sensor onto the machine
with the "X" on the level sensor base towards
the steer end of the machine. Install and
tighten the level sensor retaining fasteners.
Tip-over hazard. The tilt level
sensor must be installed with the
"X" on the level sensor base
towards the steer end of the
machine. Failure to install the tilt
level sensor as instructed could
result in the machine tipping over
causing death or serious injury.
1 chassis
2 level sensor
3 "Y" indicator
4 "X" indicator
58
GS
-2669 RT • GS
-3369 RT • GS
6
Connect the wire harness to the level sensor.
7
Turn the key switch to platform controls and
pull out the red Emergency Stop button to the
on position at both ground and platform
controls.
8
Set a multimeter to read DC voltage.
Adjust the side-to-side axis:
9
Without disconnecting the wire harness from
the level sensor, connect the negative lead of
the multimeter to the black wire at the level
sensor.
10 Without disconnecting the wire harness from
the level sensor, connect the positive lead of
the multimeter to the yellow wire at the level
sensor.
11 Adjust the "Y" axis (side-to-side) to 2.5V DC.
Tap the top of the level sensor lightly with
fingers after each turn of an adjusting nut.
Tip-over hazard. Do not adjust
the potentiometers on the bottom
of the level sensor or calibrate
the level sensor other than
specified in this procedure.
Failure to calibrate the tilt level
sensor as instructed will cause
the machine to tip over resulting
in death or serious injury.
Note: Be sure there are threads showing through
the top of the adjusting fasteners.
12 Disconnect the positive lead.
-4069 RT
May 2018
Part No. 1272219

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gs-4069Gs-3369

Table of Contents