Platform Overload Components
14 Using a small slotted screwdriver, turn the
adjustment screw of the platform overload
pressure switch one-quarter turn into the
hydraulic line.
15 Push in the ground controls red Emergency
Stop button to the off position.
16 Pull out the red Emergency Stop button to the
on position at the ground controls. Wait 3
seconds.
Result: The alarm doesn't sound. Proceed to
step 17.
Result: An alarm is sounding. Repeat this
procedure beginning with step 14.
Note: The red Emergency Stop button must be
cycled after each quarter turn of the nut (or
adjustment screw) to allow the platform overload
system to reset.
Note: Wait a minimum of 3 seconds between each
quarter turn of the nut (or adjustment screw) to
allow the platform overload system to reset.
94
GS
-2669 RT • GS
-3369 RT • GS
17 Remove the supporting device from under the
platform.
18 Raise the platform to 13 ft / 4 m.
19 Rotate the safety arm away from the machine
and let it hang down.
20 Lower the scissor assembly until the safety
arm rest on the cross tube.
21 Install the cover onto the platform overload
pressure switch or switch box and securely
tighten the cover retaining fasteners. Do not
over tighten.
22 Apply Sentry Seal to one of the cover retaining
fasteners where it contacts the platform
overload pressure switch box.
23 Raise the platform and rotate the safety arm to
the stowed position.
24 Lower the platform to the stowed position.