Genie GS-2669 Service And Repair Manual page 18

Hide thumbs Also See for GS-2669:
Table of Contents

Advertisement

May 2018
Do not top off with incompatible
hydraulic fluids. Hydraulic fluids
may be incompatible due to the
differences in base additive
chemistry. When incompatible
fluids are mixed, insoluble
materials may form and deposit
in the hydraulic system,
plugging hydraulic lines, filters,
control valves and may result in
component damage.
Note: Do not operate the machine when the
ambient air temperature is consistently above
120°F / 49°C.
Hydraulic Fluid Temperature
Range
Ambient air temperature
1 Chevron hydraulic oil 5606A
2 Petro-Canada Environ MV 46
3 UCON Hydrolube HP-5046D
4 Chevron Rando HD premium oil MV
Part No. 1272219
GS
-2669 RT • GS
-3369 RT • GS
Chevron Rando HD Premium Oil
MV Fluid Properties
ISO Grade
Viscosity index
Kinematic Viscosity
cSt @ 200°F / 100°C
cSt @ 104°F / 40°C
Brookfield Viscosity
cP @ -4°F / -20°C
cP @ -22°F / -30°C
Flash point
Pour point
Maximum continuous operating
temperature
Note: A hydraulic oil heating system is
recommended when the ambient temperature is
consistently below 0°F / -18°C.
Note: Do not operate the machine when the
ambient temperature is below -20°F / -29°C with
Rando HD Premium MV.
-4069 RT
Service and Repair Manual
Specifications
375°F / 190°C
-58°F / -50°C
171°F / 77°C
32
200
7.5
33.5
1040
3310
3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gs-4069Gs-3369