Genie GS-2669 Service And Repair Manual page 116

Hide thumbs Also See for GS-2669:
Table of Contents

Advertisement

May 2018
ID
System Ready
32
PLATFORM
START SW
FAULT
33
LEFT FRONT
OUTRIG SW FLT
34
RIGHT FRONT
OUTRIG SW FLT
35
LEFT REAR
OUTRIG SW FLT
36
RIGHT REAR
OUTRIG SW FLT
37
AUTO LEVEL
SWITCH FAULT
3812 OSCILLATE
LIMIT SWITCHES
3815 OSCILLATE
LIMIT SWITCHES
3819 OSCILLATE
LIMIT SWITCHES
3821 OSCILLATE
LIMIT SWITCHES
4021 OSCILLATE
OUTPUT
4022 OSCILLATE
OUTPUT
49
DRIVE COIL 1
FAULT
Part No. 1272219
LED Condition
Red
Engine start button fault at
platform controls.
Red
Left front outrigger enable
button fault at platform
controls.
Red
Right front outrigger enable
button fault at platform
controls.
Red
Left rear outrigger enable
button fault at platform
controls.
Red
Right rear outrigger enable
button fault at platform
controls.
Red
Outrigger auto level enable
button fault at platform
controls.
Red
Value to high. Voltage above
3000 mV.
Red
Value to low. Voltage below
1000 mV.
Red
Voltage out of range.
Red
Voltage inconsistent.
Red
Both oscillate valve outputs
are on at the same time
while elevated.
Flashing or Motion Beacon
option is set to on and it is
not installed on the machine.
Red
Oscillate valve output is
active for more than 4
seconds.
Red
Drive coil 1 (Y1) fault.
GS
-2669 RT • GS
Result
Engine will not start.
Outriggers disabled.
Outriggers disabled.
Outriggers disabled.
Outriggers disabled.
Outriggers disabled.
Elevated drive and
platform up disabled.
Elevated drive and
platform up disabled.
Elevated drive and
platform up disabled.
Elevated drive and
platform up disabled.
Elevated drive and
platform up disabled.
Elevated drive and
platform up disabled.
High speed drive
function will not
operate.
-3369 RT • GS
-4069 RT
Service and Repair Manual
Fault Codes
Solution
Troubleshoot button OR
replace printed circuit board
at platform controls.
Troubleshoot button OR
replace printed circuit board
at platform controls.
Troubleshoot button OR
replace printed circuit board
at platform controls.
Troubleshoot button OR
replace printed circuit board
at platform controls.
Troubleshoot button OR
replace printed circuit board
at platform controls.
Troubleshoot button OR
replace printed circuit board
at platform controls.
Troubleshoot oscillate limit
switches.
Troubleshoot oscillate limit
switches.
Troubleshoot oscillate limit
switches.
Troubleshoot oscillate limit
switches.
Troubleshoot oscillate limit
switches or replace ECU.
Set the option to off if not
installed on the machine.
Troubleshoot oscillate limit
switches or replace ECU.
Troubleshoot coil OR wiring.
101

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gs-4069Gs-3369