Message
cccc 5555 5535 6
cccc 5555 5565 6
cccc 5555 5551 6
cccc 5555 5553 6
cccc 5353 5555 6

Status Channel = 7 (Alarm condition)

NOTES: Each channel that displays these message types corresponds to a particular type of
event. Because there are eight channels, it is possible for multiple events to be reported in
multiple channels in only one message.
(Example: "cccc 1553 5555 7" indicates an alarm on zone 1 and a restore on zone 4.)
Message
cccc zzzz zzzz 7
6-10
Definition
S ys te m S upe rvis ory Fa ult Re s tore
S ys te m S upe rvis ory Fa ult P re vious ly Re porte d
Wa lk Te s t
Wa lk Te s t Exit
Exiting Ba tte ry Cha rge Mode
Definition
Zone Fa ult
z = zone numbe r corre s ponding to the cha nne l pos ition
(1 – 8)
1 = ne w zone fa ult
2 = ope ning (s ys te m dis a rme d)
3 = zone re s tore
4 = clos ing (s ys te m a rme d)
5 = norma l zone condition
6 = pre vious ly re port zone fa ult
Exa mple :
1234 5515 5555 7 indica te s a ne w a la rm on zone 3.
1234 5165 5555 7 indica te s a ne w a la rm on zone 2, with
a pre vious ly re porte d, un-re s tore d condition s till on zone
3. (i.e . The '6' in the third cha nne l indica te s tha t
pre vious ly, zone 3 ha d gone into a la rm, wa s re porte d in a
me s s a ge with a 1 in cha nne l thre e , a nd re ma ins
viola te d.)
1234 5335 5555 7 indica te s a re s tore on zone s 2 a nd 3.
I.e . the conditions tha t ca us e d the a la rm on zone s 2 a nd
3 ha ve re turne d to a norma l s ta te .
Note : S e nding re s tora l s igna ls a re optiona l in
progra mming.
Exa mple :
1234 5525 5555 7 indica te s a n Ope ning me s s a ge .
1234 5545 5555 7 indica te s a Clos ing me s s a ge .
Ope n/Clos e s igna ls a re typica lly s e nt via the Control
P a ne l's Dia le r; howe ve r the y ma y be optiona lly
progra mme d to be s e nt via the ra dio a s we ll.
Ope n/Clos e me s s a ge s will be s e nt on a pa rticula r
cha nne l whe n the ra dio is progra mme d prope rly a nd