Installing The Lte Mini-Pim - Juniper SRX300 Series Reference Manual

High memory gateway interface modules
Hide thumbs Also See for SRX300 Series:
Table of Contents

Advertisement

Installing the LTE Mini-PIM

The LTE Mini-PIM can be installed in any of the Mini-PIM slots on the services gateway.
NOTE:
You can install only one LTE Mini-PIM in a services gateway.
To install the LTE Mini-PIM in a services gateway:
1. Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to
the grounding point on the back of the services gateway.
2. Power off the services gateway by briefly pressing the Power button on the front panel. Wait for the
Power LED to turn off before proceeding. Disconnect the services gateway from the power source.
3. Remove the blank Mini-PIM installed on the services gateway:
a. Loosen the screws on the faceplate of the blank Mini-PIM.
b. Grasp the screws on each side and remove the blank Mini-PIM.
4. Remove the LTE Mini-PIM from the electrostatic bag.
5. Grasp the screws on each side of the Mini-PIM faceplate and align the notches in the connector at the
rear of the Mini-PIM with the notches in the Mini-PIM slot in the services gateway.
CAUTION:
components on the Mini-PIM.
6. Slide the Mini-PIM in until it lodges firmly in the services gateway. See
Figure 12: Installing the LTE Mini-PIM
Slide the Mini-PIM straight into the slot to avoid damaging the
Figure 12 on page
81.
81

Advertisement

Table of Contents
loading

This manual is also suitable for:

Srx550

Table of Contents